E1185: Glink, 3D variables could be displayed incorrectly in 5250 mode

Product: Glink Enterprise Edition 8.1
Platform: Windows
Status: Fixed in 7.2.7, 8.0.7, 8.1.3
Last updated: 2008-06-13 10:21:05

This problem could occur if you enhanced variable field display
using the 3D feature of screen facelifting configuration in 5250
mode. If the host used the technique of overlaying one form with
another form, then some of the underlying variables could retain
their 3D effects despite no longer being fields in the overlaid form.

Work around is to minimize and restore the Glink window to obtain a
correct display of the overlaid form.